In nondestructive testing, to locate the faults, we send an ultrasonic signal and measure the resulting vibration at different points. To describe and combine the uncertainty corresponding to different measurements and fuzzy estimates, we used fuzzy logic. As a result, we get reasonably simple computational models which lead to as good fault detection as the known more complicated models.